The repair had the following specifications:
Structure | Tank Roof |
Scope | Technowrap pressure containment repairs and protective coating refresh |
Surface Preparation | Sa2.5 |
Technowrap Fibre | Carbon (triaxial) Glass (triaxial) |
Design Pressure | 0.14 bar |
Design Temperature | 75°C |
Design Life | 20 years |
Wrap /Repair Length | 500 mm square patches |
Number of Patches | 18 |
Defect Diameter | 50mm |
Defect Type | Multiple through wall defects |
Design Code | ISO 24817 |
The roof of a 14m diameter Ammonia Tank had experienced significant wall thinning due to external corrosion and coating breakdown. TechnowrapTM patches were applied in accordance with ISO 24817 to defect locations requiring pressure containment and the whole tank roof coating was refreshed. ICR.IAS JV supplied a 4 man multi-skilled team able to perform “low dust” blasting surface preparation, coating and TechnowrapTM repairs.
Leave your contact details along with any relevent project descriptions and photos, and we will get back to you with a solution.